Hospitaity Enviro Tech Hanna Dedicated Conductivity/TDS/Salinity Meter

This Dedicated Conductivity/TDS/Salinity Meter has salinity range of 0.0 to 400.0%, salinity resolution of 0.1%, and salinity accuracy of ±1%.

SKU: HETCMSM-238 Category:

Technical Specifications

EC Range 0.00 to 29.99 vs./cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)
EC Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ±1% Of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 Point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% Of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration Through EC calibration
EC/TDS Temperature Compensation Automatic 23 ºF to 212 ºF (-5 ºC to 100 ºC); NoTC – nonabsolute conductivity.
Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor 0.40 to 0.80
Salinity (% NaCl) Range 0.0 to 400.0% NaCl
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (% NaCl) Calibration Single point with HI 7037L Standard
Salinity (PSU) Range 2.00 to 42.00 PSU
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±1% Of reading
Salinity Range 0.0 to 80.0 g/L
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ±1% Of reading
Temperature Range -4.0 to 248.0 °F (-20.0 to 120.0 ºC)
Temperature Resolution 0.18 ºF (0.1 ºC)
Temperature Accuracy ±0.9 ºF (±0.5 ºC)
EC/TDS Probe HI763100 EC/Temperature probe
Logging Type Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot
Logging Memory Up to 1000 Records
Connectivity 1 Micro-USB port for charging and PC connectivity, 1 USB port for storage
GLP yes
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 V DC Adapter (included)
Environment (0 ºC to 50 °C) RH max 95% non-condensing
Dimensions 8 in x 5.5 in x 0.5 in (202 mm x 140 mm x 12.7 mm)
Weight 8.82 lb. (250 g)

Reviews

There are no reviews yet.

Be the first to review “Hospitaity Enviro Tech Hanna Dedicated Conductivity/TDS/Salinity Meter”

Your email address will not be published. Required fields are marked *

Scroll to Top