Technical Specification
| Power supply | Rechargeable lithium-ion battery pack 9.6 V, backup charger. |
| Battery indicator | Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after 1 minute. |
| Power consumption | Current consumption of normal test 490 mA, continuous working for 8 hours. |
| Display mode | LCD color screen, 640 dots × 480 dots, 5.6 inches, display domain: 4.56 in x 3.46 in (116 mm × 88 mm.) |
| Size of clamp | 10 A small sharp current clamp: 0.29 in x 0.51 in (7.5 mm × 13 mm);
100 A circle current clamp: 1.37 in x 1.57 in (35 mm × 40 mm); 1000 A circle current clamp: 2.67 in x 2.67 in (68 mm × 68 mm.) 6000 A Flexible Coil Current Sensor (with Integrator): 11.8 in (300 mm) |
| Instrument dimensions | 9.44 in x 6.69 in x 2.67 in (240 mm×170 mm× 68 mm.) |
| Number of channels | 4U/4I. |
| Phase-to phase voltage | 1.0 V to 2000 V. |
| Phase-to-neutral voltage | 1.0 V to 1000 V. |
| Current | 10 A current clamp: 10 mA to 10.0 A;
100 A current clamp: 0.10 A to 100 A; 1000 A current clamp: 1.0 A to 1000 A; 6000 A Flexible Coil Current Sensor (with Integrator): 10 A to 6000 A |
| Frequency | 40 Hz to 70 Hz. |
| Parameters of electricity | W, VA, Var, PF, DPF, cos φ, tan φ. |
| Energy parameters | Wh, Varh, Vah. |
| Harmonic | Order 0 to 50. |
| Total harmonic distortion | Order 0 to 50, each phase. |
| Expert mode | Yes. |
| Number of Transient records | 150 sets. |
| Voltage flicker | Yes. |
| Starting current mode | Yes, 100 seconds. |
| 3 phases unbalance | Yes. |
| Record | 300 days (simultaneous recording 20 parameters, record one point every 5 seconds). |
| Min/Max recorded value | Measurement of maximum and minimum values over a period of time. |
| Alarm | 40 different types of parameter selections, 12,800 sets alarm logs. |
| Peak | Yes. |
| Phasor diagram display | Automatically. |
| Capacity of snapshots | 60. |
| Menu language | English/Chinese. |
| Communication | USB. |
| Automatic switching off | When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off. |
| In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute. | |
| Backlight function | Yes, suitable for use at night and in a dark place. |
| Length of voltage test wire | 78.74 in (300 cm) |
| Length of current sensor wire | 118.11 in (200 cm) |
| Working temperature and humidity | 14 °F to 104 °F (-10 °C to 40 °C); below 80% Rh. |
| Storage temperature and humidity | 14 °F to 140 °F (-10 °C to 60 °C); below 70% Rh. |
| Input impedance | Input impedance of test voltage: 1 MΩ. |
| Withstand voltage | Withstand 3700 V/ 50 Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell. |
| Insulation | Between instrument wiring and shell ≥10MΩ. |
| Structure | Double insulation, with insulation vibration-proof sheath. |
| Safely rules | IEC 61010 1000 V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |
| Weight
|
Host: 3.53 lb (1.6 kg) (with battery). |
| 10 A small sharp current clamp: 0.37 lb (170 g) × 4; | |
| 100 A circle current clamp: 0.419 (190 g) × 4; | |
| 1000 A circle current clamp: 1.12 lb (510 g) × 4; | |
| 6000 A Flexible Coil Current Sensor (with Integrator): 0.73 lb (330 g) × 4; | |
| Test wires and power adapter: 2.0 lb (900 g); | |