Hospitaity Enviro Tech Portable Digital 3 pH Power Quality and Energy Analyzer With 3000A CT Clamp – Voltage flicker

3-Phase Power Analyzer: Digital, Portable, 3000A CT Clamp (10 A to 6000 A). Colour LCD, Data Logging, Alarms, Harmonics (0 to 50).

SKU: HETPHM-172 Category:

Technical Specifications

Power supply Rechargeable lithium-ion battery pack 9.6 V, backup charger.
Battery indicator Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after 1 minute.
Power consumption Current consumption of normal test 490 mA, continuous working for 8 hours.
Number of channels 4 U or 4 I
Phase to phase voltage 1.0 V to 2000 V
Phase-to-neutral voltage 1.0 V to 1000 V
Current 10 A current clamp: 10 mA to 10.0 A

100 A current clamp: 0.10 A to 100 A

1000 A current clamp: 1.0 A to 1000 A

6000 A Flexible Coil Current Sensor (with Integrator): 10 A to 6000 A

Frequency 40 Hz to 70 Hz
Parameters of electricity W, VA, Var, PF, DPF, cos φ, tan φ
Energy parameters Wh, Varh, Vah
Harmonic Order 0 to 50
Total harmonic distortion Order 0 to 50, each phase
Expert mode Yes
Number of Transient records 150 sets
Voltage flicker Yes
Starting current mode Yes, 100 sec
3 phases unbalance Yes
Record 300 days (simultaneous recording 20 parameters, record one point every 5 seconds).
Min or Max recorded value Measurement of maximum and minimum values over a period of time
Alarm 40 different types of parameter selections, 12,800 sets alarm logs
Peak Yes
Phasor diagram display Automatically
Capacity of snapshots 60
Communication USB
Automatic switching off When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off
Backlight function Yes, suitable for use at night and in a dark place.
Input impedance Input impedance of test voltage: 1 MΩ
Withstand voltage Withstand 3700 V per 50 Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell
Insulation Between instrument wiring and shell ≥ 10 M Ω
Structure Double insulation, with insulation vibration proof sheath
Safely rules IEC 61010 1000 V Cat III or 600 V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2
Working temperature and humidity 14 °F to 104 °F (-10 °C to 40 °C) below 80 % RH
Storage temperature and humidity 14 °F to 140 °F (-10 °C to 60 °C)  below 70 % RH
Display mode LCD colour screen, 640 dots × 480 dots, 5.6 inches, display domain: 4.56 in x 3.46 in (116 mm × 88 mm)
Size of clamp 10 A small sharp current clamp: 0.29 in x 0.51 in (7.5 mm × 13 mm)

100 A circle current clamp: 1.37 in x 1.57 in (35 mm × 40 mm);

1000 A circle current clamp: 2.67 in x 2.67 in (68 mm × 68 mm.)

6000 A Flexible Coil Current Sensor (with Integrator): 11.8 in (30 cm)

Instrument dimensions 9.44 in x 6.69 in x 2.67 in (24 cm×17 cm× 6.8 cm)
Length of voltage test wire 78.74 in (300 cm)
Length of current sensor wire 118.11 in (200 cm)
Weight Host: 3.53 lb (1.6 kg) (with battery)

10 A small sharp current clamp: 6 oz (170 g) × 4

100 A circle current clamp: 6.7 oz (190 g) × 4

1000 A circle current clamp: 17.99 oz (510 g) × 4

6000 A Flexible Coil Current Sensor (with Integrator): 11.64 oz (330 g) × 4

Test wires and power adapter: 31.75 oz (900 g)

Total Weight 20.28 lb (9.2 kg)
Scroll to Top