Hospitaity Enviro Tech Lab Water Testing Conductivity Multi-Parameter Meter

Hospitaity Enviro Tech Lab Water Testing Conductivity Multi-Parameter Meter is one meter with several measuring units.

SKU: HETLCM-237 Category:

Overview

Hospitaity Enviro Tech Lab Water Testing Conductivity Multi-Parameter Meter is one meter with several measuring units. It can measure simultaneously pH/pX, Ion concentration, ion electrode potential (mV) value, Conductive (conductivity, TDS, salinity), DO (concentration and saturation) and temperature, etc.

 

Features

  • 3″ LCD touchscreen with high contrast
  • Intelligent operation system for various management
  • Multi-reading: auto, timed, continuous
  • Auto/Manual temperature compensation
  • Auto-hold for measurement stability
  • 1000 sets storage per parameter (GLP)
  • Data analysis for review and comparison
  • USB communication support
  • Auto-power off for extended battery life
  • Reset to factory defaults
  • IP65 waterproof rating

 

Technical Specifications

Parameters pH or EC or ISE or Temp. (mV or ORP or pX or Resistivity or TDS or Sal.)
pH
Range -2 pH to 20 pH
Resolution 0.1 pH, 0.01 pH, 0.001 pH
Accuracy ±0.002 pH
Calibration Points Up to 8
Standard Customization Yes
Calibration Reminder Yes
Standard Recognition USA, NIST, MERK, JIS, GB and DIN buffers
Slope Limit Yes
mV/ORP
Range -2000 mV to 2000 mV
Resolution 0.1 mV, 0.01 mV
Accuracy ±0.1 mV or ±0.03%
EH ORP Mode Yes
ORP Calibration Points 1 custom point (relative mV)
pX
Range -2.000 pX to 20.000 pX
Resolution 0.1 pX, 0.01 pX, 0.001 pX
Accuracy ±0.002 pX
Calibration Points Up to 6
ISE
Range 1 e-9 to 9.999 e9
Units mol/L, mmol/L, g/L, mg/L, μg/L
Resolution Up to 4 significant digits
Accuracy ±0.3%
Calibration Points Up to 8
Conductivity
Range 0 μS/cm to 3000 mS/cm
Resolution 0.001 μS/cm minimum, various with range selection
Accuracy ±0.5% FS
Calibration Points Up to 5
Calibration Reminder Yes
Standard Recognition 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm
Resistivity
Range 5.00 Ω·cm to 100.00 MΩ·cm
Resolution 0.01 Ω·cm minimum
Accuracy ±0.5% FS
TDS
Range 0 mg/L to 1000 g/L
Resolution 0.001 mg/L minimum, changed with range
Accuracy ±0.5%
Salinity
Range 0.00% to 8.00%
Resolution 0.01%
Accuracy ±0.1%
Temperature
Unit °C, °F
Resolution 0.1
Relative Accuracy ±0.1
Measurement
Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts Reading, Stable, Locked
Temp. Compensation ATC, MTC
Data management Data Storage 1000 Groups
Conductivity Reference Temperature 41 ℉, 50 ℉, 59 ℉, 64.4 ℉, 68 ℉, and 77 ℉ (5 ℃, 10 ℃, 15 ℃, 18 ℃, 20 ℃, and 25 ℃)
Temperature Range 14 ℉ to 275 ℉ (-10 ℃ to 135 ℃)