Features
- Innovative sensor design minimizes measurement variations caused by device angle or contact pressure
- Consistent data quality at both low and high frequency ranges
- Four-level severity scale assesses urgency of problems for overall vibration and bearing condition
- Exportable data via USB
- Trending in Microsoft Excel using pre-built templates
- Overall vibration measurement (10 Hz to 1,000 Hz) for acceleration, velocity and displacement units of measurement
- Crest Factor+ technology provides reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
- Compare vibration levels with ISO-10816 severity scales and store
Technical Specifications
| Low Frequency Range (overall measurement) |
10 Hz to 1,000 Hz |
| High Frequency Range (CF+ measurement) |
4,000 Hz to 20,000 Hz |
| Severity Levels | Good, Satisfactory, Unsatisfactory, Unacceptable |
| Vibration Limit | 50 G peak (100 G peak-peak) |
| A/D Converter | 16-bit |
| Signal To Noise Ratio | 80 dB |
| Low Frequency | 20,000 Hz |
| High Frequency | 80,000 Hz |
| Real Time Clock Backup | Coin battery |
| Sensitivity | 100 mV / g ± 10% |
| Measurement Range | 0.01 G to 50 G |
| Low Frequency Range (overall measurement) |
10 Hz to 1,000 Hz |
| High Frequency Range (CF+ measurement) |
4,000 Hz to 20,000 Hz |
| Resolution | 2.204623e-5 lbs (0.01 g) |
| Accuracy | At 100 Hz ± 5 % of measured value |
| Range | -4 °F to 392 °F (-20 °C to 200 °C) |
| Accuracy | ±4 °F (2 °C) |
| Focal Length | Fixed, at to 1.50 in (3.8 cm) |
| Frequency Range | 10 Hz to 1,000 Hz |
| Bias Voltage (to supply power) | 20 V dc to 22 V dc |
| Bias Current (to supply power) | Maximum 5 mA |
| Calibration | Factory calibration required |
| External Interfaces | USB 2.0 (full speed) communication |
| Data Capacity | Database on internal flash memory |
| Upgrade | Through USB |
| Memory | Up to 3,500 measurements |
| Electrostatic Discharge: Burst | Standard EN 61000-4-2 |
| Electromagnetic Interference | Standard EN 61000-4-3 |
| RE | Standard CISPR 11, Class A |
| Operating Temperature |
-4 °F to 122 °F (-20 °C to 50 °C) |
| Storage Temperature |
-22 °F to 176 °F (-30 °C to 80 °C) |
| Vibration Limit | 500 G peak |
| Battery Type | AA (2) Lithium Iron Disulfide |
| Battery Life | 250 measurements |
| Size (L x W x H) | 10.13 in x 6.38 in x 3.875 in (25.72 cm x 16.19 cm x 9.84 cm) |
| Weight | 2.55 lb (1.16 kg) |








Reviews