Hospitality Enviro Tech Winding Insulation Resistance Tester with precision design is suitable for testing the insulation resistance of most primary and secondary equipment such as cable and transformers. It is used to determine the initial insulation condition of the device. The tester can easily measure the absorption ratio and polarization index, which can eliminate human calculation error.

 

Technical Specifications

Rated voltage (Insulation Resistance Test) 250 V
500 V
1000 V
2500 V
5000 V
Test Range (Insulation Resistance Test) 0.25 MΩ to 99.99 MΩ
80 MΩ to 600 MΩ
0.5 MΩ to 99.99 MΩ
80 MΩ to 1000 MΩ
1.00 GΩ to 1.2 GΩ
1.0 MΩ to 99.99 MΩ
80 MΩ to 999.9 MΩ
1.00 GΩ to 2.2 GΩ
2.5 MΩ to 99.99 MΩ
80 MΩ to 999.9 MΩ
0.8 GΩ to 9.999 GΩ
8.0 GΩ to 99.99 GΩ
80 GΩ to 120 GΩ
5.0 MΩ to 99.99 MΩ
80 MΩ to 999.9 MΩ
0.8 GΩ to 9.999 GΩ
8.0 GΩ to 99.9 GΩ
80 GΩ to 500 G
Open Circuit Voltage (Insulation Resistance Test) DC 250 V
+20%, – 0%
DC 500 V
+20%, – 0%
DC 1000 V
+20%, – 0%
DC 2500 V
+ 20%, – 0%
DC 5000 V
+20%, – 0%
Current under rated load (Insulation Resistance Test) 0.25 MΩ load condition
1 mA to 1.2 mA
0.5 MΩ load condition
1 mA to 1.2 mA
1 MΩ load condition
1 mA to 1.2 mA
2.5 MΩ load condition
1 mA to 1.2 mA
5 MΩ load condition
1 mA to 1.2 mA
Short Circuit Current (Insulation Resistance Test) About 1.5 mA ± 0.5 mA
Accuracy (Insulation Resistance Test) ±5 % rdg ±3 % dgt or ±10% (More than 0.2 lb Ω (100 g Ω))
Test range  (Voltage Test Range) D.C Voltage : ±30 V to ±600 V
A.C Voltage : 30 V to 600 V (50 Hz or 60 Hz)
Resolution Ratio (Voltage Test Range) DC -1 V,AC -5 V
Accuracy (Voltage Test Range) ±2 % rdg ±3 dgt
Working Conditions Below 2.1 mi (2000 m)
Operating Temperature 14   ºF to 104 ºF (- 10 ºC to 40 º C)
Storage Temperature -4 ºF to 140 ºF (- 20 ºC to 60 ºC)
Humidity Operating: 90% RH max. at 104 ºF (40 °C)
Voltage Withstand AC 5160 V(50 Hz or 60Hz) or 5s (Between the circuit and the enclosure)
Insulation Resistance ≥1000 MΩ or DC 1000 V (Between the circuit and the enclosure)
Power Li-ion Battery DC 12 V
Electricity Energy Parameter W, VA, var, PF, DPF, cosφ, tanφ ; Wh, Varh, Vah
Number of Channels 4 voltages, 4 currents
Three Phase Unbalance
Y
Frequency 40 Hz to 70 Hz
Start Current Mode
Y, 100 seconds
Harmonic Wave 0 times to 50 times
Peak Value
Y
Total Harmonic Distortion Y, 0 times to 50 times, each phase
Phasor Diagram Display
Automatic
Expert Mode Y
Screenshot Capacity
60 PCS
Number of Transient Record groups 150 set
Menu Language
Chinese, English