Features
- Function Insulation resistance test, voltage test, current test, capacitance test
- Rated applied voltage 250 V, 500 V, 1000 V, 2500 V, 5 KV, 10 KV
- Resistance limit range 0.01 MΩ to 10 TΩ
- Resolution 0.01 MΩ
- Accuracy ±3% rdg±5 dgt
- Output short-circuits current ≥5 mA
Technical Specifications
| Rated Test Voltage | 250 V, 500 V, 1000 V,2500 V, 5 KV, 10 KV |
| Measuring Range | 0 MΩ to10 TΩ |
| Output Voltage Error | ±5% |
| Short Circuit Current | About 5 mA |
| Accuracy Level | Grade 3.0 |
| Basic Error of Lower Half Range | ± (2% Rx+1d) |
| Basic Error of Upper Half Range | ± (3% Rx+2d) |
| Display Range and Error of Leakage Current | 0.1 nA to 9.9 mA, 5% |
| Absorption Capacitance Display Range and Error | 0.1 pF to 99 μF,5% |
| Temperature Measurement Error | 33.9 ℉ (±0.5 ℃) |
| Air Humidity Measurement Error | ±2%RH |
| Power Supply | 14.8 V lithium battery |
| One Time Charging Service Time of Battery | About 30 days |
| Insulation Resistance | More than 500 MΩ |
| Power Frequency Withstand Voltage | AC 10.0 kV 50 Hz 1 min |
| Operating Temperature and Humidity | 32 ℉ to 104 ℉ (0 ℃ to +40 ℃) ≤85% RH |
| Storage Temperature and Humidity | -4 ℉ to 122 ℉ (-20 ℃ to +50 ℃) ≤90% RH |
| Outline Size | 11.81 in x 10.63 in x 5.91 in (300 mm ×270 mm × 150 mm) |
| Weight | 7.71 lb (3.5 kg) |









Reviews
There are no reviews yet.