Hospitality Enviro Tech Industrial Scope Meter Hand-Held Oscilloscope

Hospitality Enviro Tech Industrial Scope meter Hand-held Oscilloscope work with confidence with this oscilloscope that offers simplified testing, more insight, faster electro-mechanical troubleshooting, and comes with 20 MHz of bandwidth.

SKU: HETMOS-104 Category:

Overview

Hospitality Enviro Tech Industrial Scope meter Hand-held Oscilloscope work with confidence with this oscilloscope that offers simplified testing, more insight, faster electro-mechanical troubleshooting, and comes with 20 MHz of bandwidth. Conveniently provides full-function dual input scope and meter measurements

Features

  • 123 B/NA Industrial Scope Meter Handheld Oscilloscope 20 MHz
  • Dual-input digital oscilloscope and multimeter
  • 20 MHz oscilloscope bandwidth
  • Two 5,000-count true-rms digital multimeters
  • Connect-and-View trigger simplicity for hands-off operation
  • Intel Set™ technology automatically and intelligently adjusts numerical readout based on the measured signal
  • Dual-input waveform and meter reading recorder for trending data over extended periods
  • Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
  • Shielded test leads for oscilloscope, resistance and

 

Technical specification

Frequency Response – DC Coupled Without probes and test leads (with BB 120): DC to 20 MHz (-3 dB)With STL120 to IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)

With VP41 10:1 probe: DC to 20 MHz (-3 dB)

Frequency Response – AC Coupled (LF Roll Off) Without probes and test leads: < 10 Hz (-3 dB)With STL120-IV 1:1 shielded test leads: < 10 Hz (-3 dB)

With VP41 10:1 probe: < 10 Hz (-3 dB)

Rise Time, Excluding Probes, Test Leads < 17.5 ns
Input Impedance Without probes and test leads: 1 MΩ / 20 pFWith BB120: 1 MΩ / 24 pF

With STL120-IV 1:1 shielded test leads: 1 MΩ / 230 pF

With VP41 10:1 probe: 5 MΩ / 15.5 pF

Sensitivity 5 mV to 200 V/div
Analog Bandwidth Limiter 10 kHz
Display Modes A, -A, B, -B
Maximum Input Voltage A and B Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltageWith BB120: 600 Vrms
Maximum Floating Voltage, from any Terminal to Ground 600 Vrms CAT IV, 750 Vrms up to 400 Hz
Oscilloscope Mode (Horizontal)
Scope Modes Normal, single, roll
Ranges (Normal) Equivalent sampling: 20 ns to 500 ns/divReal time sampling: 1 μs to 5 s/div

Single (real time): 1 μs to 5 s/div

Roll (real time): 1 s to 60 s/div

Sampling Rate (for Both Channels Simultaneously) Equivalent sampling (repetitive signals): up to 4 GS/sReal time sampling 1 μs to 60 s/div: 40 MS/s
Trigger
Screen Update Free run, on trigger
Source A, B
Sensitivity A and B At DC to 5 MHz: 0.5 divisions or 5 mVAt 40 MHz: 4 divisions
Slope Positive, negative
Advanced Scope Functions
 

 

Frequency

Ranges: 1 Hz, 10 Hz, 100 Hz, 1 KHz, 10 KHz, 100 kHz, 1 MHz, 10 MHz, and 50 MHzFrequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset

Accuracy at 1 Hz to 1 MHz: ± (0.5 % + 2 counts)

Full scale reading: 10,000 counts

Input A to Common
Ohm Ranges: 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩAccuracy: ± (0.6 % + 5 counts) 50 Ω ± (2 % + 20 counts)

Full scale reading: 50 Ω to 5 MΩ to 5000 counts; 30 MΩ to 3000 counts

Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges

Open circuit voltage: < 4 V

General Specifications
EMC Electromagnetic Compatibility USA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103)
Enclosure Protection IP51, ref: EN/IEC60529
Safety General: IEC 61010-1: Pollution Degree 2Measurement: IEC 61010 to 2-033: CAT IV 600 V/CAT III 750 V
Memory Internal memory can store 20 data sets (screen waveform and setup)Micro SD card slot with optional SD card (maximum size of 32 GB)
Dimensions 10.2 in x 5.2 in x 2.15 in (259 mm x 132 mm x 55 mm)
Weight 3.2 lb (1.4 kg) including battery pack

Reviews

There are no reviews yet.

Be the first to review “Hospitality Enviro Tech Industrial Scope Meter Hand-Held Oscilloscope”

Your email address will not be published. Required fields are marked *