Features
- Superpower emission, Ultra-low noise receives, first-wave auto gain control system
- The face-test penetration range can reach 10 M in undefective concrete
- Accurate and rapid automatic read-in and analysis of acoustic wave transit time
- Fluctuation range guarantees the reliability and efficiency of the test data
- Markedly improves the detection speed
- Real-time display and automatic saving of the plotted graph of pile integrity
- The location of test points
- The acoustic wave transit time of the first wave, the waveform, the wave range etc
- Without losing interruption of power supply
- Arbitrarily retest and redisplay of the sampling waveform of every test point
- Preventing the error in on-site testing and on-site judgment. Convenient and rapid
- System provides private port for the power supply to radical transducer, convenient, safe
- High-reliability industrial-grade dedicated control system, high definition, bright
- TFT true color LCD, with stable and reliable performance;
- Internal high energy lithium battery, instant charging (no memory)
- Capable of outdoor continuous operation over extended time periods
- Standard USB ports, support U disk
- Small size, light weight
- Professional analysis-processing software generates and prints test reports
Technical Specifications
| Sampling interval | 0.025 μs to 1638.4 μs adjustable |
| Acoustic transit time accuracy | 0.025 μs |
| Dynamic range | 154 dB |
| Receiver sensitivity | ≤10 μv |
| Emission voltage(V) | 65,250,500,1000 V adjustable |
| Size(mm) | 8.26 in × 5.88 in × 2.36 in (210 mm × 149 mm × 60 mm) |
| Temperature | 14 °F to 104 °F (-10 ℃ to +40 ℃) |
| Power | 220 V AC/DC |
| Battery time | >5 h rs |
| Amplifier bandwidth | 3 kHz to 450 kHz |
| Gain error | 0.5 dB |
| Weight | 2.99 lb (1.36 kg) (lithium battery included) |