Hospitality Enviro Tech Circuit Transformer Ratio Parameter Tester

Hospitality Enviro Tech circuit transformer ratio parameter tester can be used for quality supervision of transformer, to prevent the transformer inter-turn short circuit, open circuit, connection error, voltage regulating switch internal fault or contact failure.

SKU: HETCPT-215 Category:

Overview

Hospitality Enviro Tech circuit transformer ratio parameter tester can be used for quality supervision of transformer, to prevent the transformer inter-turn short circuit, open circuit, connection error, voltage regulating switch internal fault or contact failure. we develop the production of automatic ratio tester according to the user’s requirements on-site using, make the operation more convenient, complete functions, reliable data, test speed is greatly improved. To meet the needs of all kinds of small medium and large transformer test.

 

Features

  • English menu prompts, easy to operate
  • The measurement range of ratio 1 to 9999.9
  • Both single phase measurement can be achieved
  • Achieve the automatic test of three-phase windings
  • The connection group can be arbitrarily selected
  • Measurement of AB, BC, CA three-phase variable ratio, error
  • Measurement of line group parameters
  • Fast measuring speed
  • Once the measurement is completed, automatic cut off the test power
  • Set data, automatic measurement results, can view the previous data
  • Test transformer on-load, only need once input ratio
  • Easy to carry, suitable for field operations

 

Technical Specifications

Working power Input voltage 185 V AC to 250 V AC
Working power allowable voltage 85 V AC to 264 V AC
Working power frequency 50 Hz or 60 Hz
Working power allowable frequency 45 Hz to 65 Hz
Working input power 40 VA
Working power Joint Standard AC socket 60320
Measuring ratio test range 1 to 9999.9
Measuring group test range 1 to 12
Test accuracy 1% to 999.99%, 0.2%, 1000% to 9999.9%, 0.5%
Resolving power Relative humidity 5% to 95%, No dew
Environmental accuracy 0.2% ± 0.001 A
Frequency resolving power 0.001 Hz
Frequency accuracy 0.2% ± 0.001 Hz
Power range 0 W to 39 kW
Resolving power 0.001 kW
Power accuracy <±0.5% (CosΦ>0.1), ±1.0% (0.02< CosΦ<0.1)
10kV Dry type transformer 30 kVA to 3150 kVA
10kV Oil immersed transformer 30 kVA to 31500 kVA
35kV Oil immersed transformer 50 kVA to 31500 kVA
20kV Dry type transformer 50 kVA to 2500 kVA
35kV Dry type transformer 50 kVA to 2000 kVA
Operating temperature 14 °F to 122 °F (-10 ℃ to 50 ℃)
Storage temperature -13 °F to 158 °F (-25 ℃ to 70 ℃)
Size 15.7 in x 11.4 in x 6.6 in (400 mm × 290 mm × 170 mm)
Weight 15.4 lb (7 kg)