Hospitality Enviro Tech Sensitive Multi-Parameter Monitor

This Sensitive Multi-Parameter Monitor has a pH range of -2 pH to 20 pH, mV resolution of 0.1 mV, and pX accuracy of ±0.01 pX.

SKU: HETIMWA-253 Category:

Features

  • 5″ LCD display screen
  • Multi-reading: auto, timed, continuous
  • Auto/Manual temp compensation for accuracy
  • Auto-hold locks measurement endpoint
  • Data capacity: 500 sets (GLP-compliant)
  • USB communication support
  • Auto-power off for extended battery life
  • Reset restores factory default options
  • IP65 waterproof rating

 

Technical Specifications

Parameters pH/EC/ISE/DO/Temp. (mV/pX/Resistivity/TDS/Sal. /DO Saturation)
pH
Range -2 pH to 20 pH
Resolution 0.1, 0.01 pH
Accuracy ±0.01 pH
Calibration Points Up to 5
Standard Customization Yes
Calibration Reminder Yes
Standard Recognition NIST, GB and DIN buffers
Slope Limit Yes
mV
Range -2000 mV to 2000 mV
Resolution 0.1 mV
Accuracy ±0.3 mV or ±0.1%
pX
Range -2 pX to 20 pX
Resolution 0.1 pX, 0.01 pX
Accuracy ±0.01 pX (±0.01 pX)
Calibration Points Up to 5
ISE
Range 1 e-9 to 9.999 e9
Units mol/L, mmol/L, g/L, mg/L, μg/L
Resolution Up to 4 significant digits
Accuracy ±0.5%
Calibration Points Up to 5
Conductivity
Range 0.000 μS/cm to 1000 mS/cm
Resolution 0.001 μS/cm minimum
various with range selection
Accuracy ±1.0% FS
Reference Temperature 68 °F, 77 °F (20 °C, 25 °C)
Calibration Points Up to 3
Standard Recognition 84 μS/cm, 1413 μS/cm, 12.88 mS/cm
Resistivity
Range 5 Ω·cm to 20 MΩ·cm
Resolution 0.01 Ω·cm minimum
Accuracy ±1.0% FS
TDS
Range 0.00 mg/L to 300 g/L
Resolution 0.01 mg/L minimum, 3 significant digits
Accuracy ±1.0%
Salinity
Range 0% to 8%
Resolution 0.01%
Accuracy ±0.2%
Dissolved Oxygen Concentration
Sensor Type 0 mg/L to 50 mg/L
Range 0 mg/L to 50 mg/L
Resolution 0.01 mg/L
Accuracy ±0.1 mg/L
Calibration Points Air-saturated water or zero point
Barometric Compensation Yes
Manual Salinity Factor Correction Yes
Saturation
Range 0% to 300%
Resolution 0.10%
Accuracy ±2%
Temperature
Range 41 °F to 230 °F (-5 °C to 110 °C)
Unit °C, °F
Resolution 0.1
Relative Accuracy ±0.2
Measurement
Reading Mode Auto-Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts Reading, Stable, Locked
Temp. Compensation ATC, MTC
Data Management
Data Storage 1000 Groups
GLP Features Yes
Inputs
pH Electrode BNC(Q9)
DO with Temp. Probe 4-pin aviation connector
Conductivity with Temp. Probe 5-pin aviation connector
Outputs
USB PC, printer
Display Options
Backlight Yes
Auto Shutdown 300 sec., 600 sec, 1200 sec, 1800 sec, 3600 sec., off
IP Rating IP 65
Date and Time Yes
General
Power Rechargeable Lithium battery, AC Adapter, 100 V to 240 V AC input, DC 5 V output
Dimensions 3.54 in × 10.03 in × 1.57 in (90 mm x 255 mm x 40 mm)
Weight  1.1 lb. (500 g)

Reviews

There are no reviews yet.

Be the first to review “Hospitality Enviro Tech Sensitive Multi-Parameter Monitor”

Your email address will not be published. Required fields are marked *